sales01@gdtym.com
sales01@gdtym.com
+86 188 1411 5468
Free Quote

Liquid Silicone Rubber Pessary Ring – Cold-Runner Medical Molding Solution

TYM’s 6-cavity cold-runner LSR solution for medical silicone pessary rings. Horizontal machine, flash-free seamless surface, implant-grade material, controlled manual demolding.

Cavities
6
Liquid silicone rubber uterine support injection mold - TYM
Liquid silicone vaginal support device - TYM
undefined
Liquid silicone rubber uterine support injection mold - TYM
Liquid silicone vaginal support device - TYM

Core Technology Breakdown

TYM Horizontal LSR Injection Molding Machine

A pessary ring is a thin, closed-loop section that must fill evenly all the way around. Any imbalance shows up as a weld line or a soft spot in the finished ring.

    • ▸ Horizontal clamping with even platen pressure across the full 6-cavity layout, which is what keeps the parting line tight on the outer cavities as well as the center ones.

    • ▸ LSR metering and mixing system with precision injection unit for consistent shot-to-shot repeatability

    • ▸ Closed-loop servo control for consistent shot weight across all cavities

    • ▸ Profiled low-pressure injection fills the thin ring section completely without over-packing the parting line, which is the usual root cause of flash on this geometry.

    • ▸ Integrated temperature control for both mold and injection unit, holding tight process windows for automotive-grade LSR compounds

    • ▸ Stored, repeatable parameter sets, which supports process validation and lot-to-lot documentation required for medical production.
    •  

6-Cavity Cold-Runner Mold

By using a single and precisely balanced cold-flow system to supply materials to all 6 cavities, this is of crucial importance for the quality of the hysterophore:

      • ▸ Balanced flow distribution ensures even fill across all 6 cavities

      • ▸ Eliminates overfill or short-shot defects common in high-cavitation LSR molds

      • ▸ Precise pressure and temperature control throughout the cold-runner channels

      • ▸ Optimized venting prevents trapped air, short shots, and burn marks where the flow fronts meet on a closed ring.

      •  

Result: Every ring has the same diameter, cross-section, and flexibility, with a surface that requires no secondary operation of any kind.

Controlled Manual Demolding

A pessary ring is soft, thin, and must leave the mold without a single scratch, stretch mark, or surface defect. On this product we demold by hand deliberately rather than by robot:

    • ▸ Operator-controlled release lets the ring be eased evenly off the core, instead of a fixed mechanical stroke stretching one side of a flexible closed loop.

      • ▸ Each piece is visually checked as it is removed, so a defect is caught at the machine rather than downstream — practical on a medical product where 100% inspection is expected anyway.

      • ▸ Gloved, contamination-controlled handling throughout, suiting cleanroom and medical-grade production requirements.

        • ▸ Parts are placed directly into trays in a defined orientation, ready for inspection, post-curing, and packaging with no further handling.
        • ▸ No mechanical gripper contact on the finished surface, which removes a whole class of surface-mark risk on a highly visible, highly inspected part.
        •  

Medical Material & Compliance

A dedicated automatic demolding (extraction) machine completes the automation loop:

    • ▸ Platinum-cured, medical-grade LSR, leaving no peroxide by-products and no leachable cure residues.

      • ▸ Material grades available to USP Class VI and ISO 10993 

        • biocompatibility requirements for long-term mucosal contact, depending on your registration route.

        inspection/packaging

      • ▸ Post-curing to drive volatile content to the lowest achievable level, as medical specifications typically require.

      • ▸ Autoclave and repeated-cleaning stable. Silicone keeps its elasticity and shape through sterilization cycles without hardening, cracking, or yellowing.
      •  
      •  

Key Benefits at a Glance

Benefit Detail
Seamless Body-Contact Surface Flash-free parting line and no gate mark — nothing to irritate mucosal tissue.
Zero-Waste Molding Cold-runner needle-valve gating: no sprues, no runners, no recycled material in a medical part.
Clean, Flash-Free Parts Precision mold design produces parts ready for use with minimal secondary finishing.
Sterilization Stable Medical-grade LSR survives repeated autoclaving with no loss of elasticity.
Fast Time-to-Market Complete turnkey solution — machine, mold, automation, and process parameters tuned and validated before shipment.
Liquid silicone rubber uterine support injection mold - TYM
Liquid silicone rubber uterine support injection mold - TYM
Liquid silicone vaginal support device - TYM

Technical Specifications

Parameter Specification
Machine Type TYM Horizontal LSR Injection Molding Machine
Injection System Servo-driven, closed-loop control
Mold Cavities 6 cavities, cold-runner design

  Runner Type

Cold-runner, self-cutting sprue-less gates

  Material

Liquid Silicone Rubber (LSR)

  Application

Pessary ring / medical silicone support device

One Supplier. One System. One Guarantee.

We deliver the horizontal machine and the 6-cavity cold-runner mold as one matched system from a single source, rather than leaving you to coordinate a machine vendor and a mold shop — which matters on a medical part, where the flash-free result depends on machine and mold being tuned as one.

No Integration Headaches:
The machine and mold are designed together to ensure optimal performance and seamless compatibility.
Single-Point Responsibility:
We take full accountability for the overall quality, performance, and after-sales service of the entire system.
Pre-Tested and Validated:
The complete system is rigorously tested, tuned, and validated as a single functioning unit before delivery.
Faster Ramp-Up:
With process parameters already configured, your team can start mass production within days of installation.

Proven in Production

Our 6-cavity LSR pessary ring solution is already running in production, delivering:

High Yield Rate:
Consistently achieves industry-leading pass rates during both visual and dimensional inspections.
Uniform Cross-Section:
Balanced 6-cavity filling keeps ring thickness and flexibility consistent around the full circumference.
Minimal Post-Processing Requirement:
Produces flash-free parts with minimized gate marks, reducing the need for deflashing or gate trimming.
Long-Term Process Stability:
Sprueless cold-runner design maintains stable output without process drift over extended production runs.

Made for Global Standards

CE-Certified Safety
All electrical components and integrated safety systems are fully CE-certified, guaranteeing safe and reliable operation in global manufacturing environments.
FDA & EU Compliant Processing:
Engineered to meet strict hygiene standards, our system is fully capable of processing food-grade and medical-grade LSR materials compliant with FDA and EU regulations.
ISO 9001 Quality Management:
Our entire workflow—from initial R&D and mold design to manufacturing and final testing—is strictly governed by ISO 9001 quality management protocols.
Comprehensive Global Support:
We provide complete English technical documentation, intuitive English PLC interfaces, and highly responsive global technical support for commissioning and troubleshooting.

Frequently Asked Questions

Projects
Can one mold produce different ring sizes?
Pessaries are supplied in a size range, so this is the first question most customers ask. The mold is built to your drawing for outer diameter and cross-section, and for a multi-size program we normally recommend either a dedicated mold per size or a common mold base with interchangeable cavity sets. Mixing significantly different diameters in one tool unbalances the fill, so we size the approach to your volume per SKU.
Why is a cold runner important for a medical part specifically?
Two reasons. It leaves no gate vestige on a body-contact surface, which removes the need to cut the part. And because nothing is cured in the runner, there is no regrind or recycled material anywhere in the process — every part is molded from virgin medical-grade LSR, which is what material traceability requires.
Does the part need post-curing?
Usually yes for long-term body-contact devices, to drive volatile content down to the level your specification and biocompatibility testing require. We can advise on the post-cure profile and include the oven in the quotation.
What training and support do you provide?
We provide on-site training for operators and maintenance technicians, complete documentation (machine manual, mold maintenance guide, process parameters), and remote technical support. Our engineers are available worldwide for on-site commissioning and troubleshooting.

Ready to Transform Your Nipple Production?

Contact us today for a free consultation, process analysis, and quotation.

We can provide production simulations, sample molding, and ROI projections tailored to your specific requirements.

Name must not exceed 100 characters.
Invalid email format or length exceeds 100 characters. Please re-enter.
Please enter a valid phone number!
Company Name must not exceed 150 characters.
Content must not exceed 3000 characters.

You May Also Like

Vertical rotary liquid silicone injection molding machine with LSR dosing system - TYM
Vertical LSR Injection Molding Machine

The vertical machine will open and close the mold in the vertical direction. The double slide plate can be installed with one upper mold and two lower molds. It can cooperate with the double station operation to improve the production efficiency, and is more suitable for the production of rubber coated products of silica gel package inserts.

Vertical LSR Injection Molding Machine
Horizontal LSR injection molding machine with liquid silicone dosing system - TYM
Horizontal LSR Injection Molding Machine

Direct pressure mold opening and closing system.It's more suitable for producing the LSR parts which can be automatically removed from the mold.It can be used for the production of silicone products in multiple industries - automotive wiring harnesses, baby pacifiers, menstrual cups, medical valve plugs.

Horizontal LSR Injection Molding Machine
Horizontal hinged LSR injection molding machine with liquid silicone feeding system - TYM
Horizontal Hinged Lsr Injection Molding Machine

Direct pressure mold opening and closing system.It's more suitable for producing the LSR parts which can be automatically removed from the mold.

Horizontal Hinged Lsr Injection Molding Machine
Horizontal 2K double-color LSR injection molding machine with silicone dosing system - TYM
Horizontal 2K / Double-color LSR Injection Molding Machine

There are two injection units, two separate feed systems and color slurry addition systems. A unified system control panel can be used to achieve two different colors or hardness of liquid silicone. Formed in the machine at the same time, Suitable for the production of double color silicone products or double hardness silicone products.

Horizontal 2K / Double-color LSR Injection Molding Machine
Scan QR Code

Get a Fast & Accurate Quote

Tell us your requirements and our engineering team will provide a tailored quotation for your LSR solution.

×
Name must not exceed 100 characters.
Invalid email format or length exceeds 100 characters. Please re-enter.
Please enter a valid phone number!
Company Name must not exceed 150 characters.
Content must not exceed 3000 characters.

Request a Customized Proposal

Share your product drawings or application details.

We will design a complete LSR manufacturing proposal for you.

×
Name must not exceed 100 characters.
Invalid email format or length exceeds 100 characters. Please re-enter.
Please enter a valid phone number!
Company Name must not exceed 150 characters.
Content must not exceed 3000 characters.

Let’s Talk With an LSR Expert

Not sure which solution fits your project?

Our engineers are here to help you evaluate and optimize your idea.

×
Name must not exceed 100 characters.
Invalid email format or length exceeds 100 characters. Please re-enter.
Please enter a valid phone number!
Company Name must not exceed 150 characters.
Content must not exceed 3000 characters.

One-Stop Turnkey LSR Solution

From mold design to automated production line integration, TYM delivers a fully customized manufacturing system tailored to your product.

×
Name must not exceed 100 characters.
Invalid email format or length exceeds 100 characters. Please re-enter.
Please enter a valid phone number!
Company Name must not exceed 150 characters.
Content must not exceed 3000 characters.